Singapore at your fingertips...     Singapore's Comprehensive Online Business Directory & Information Guide
 

Home  >  Products & Services  >

 
Aircraft Ground Support & Service Eqpt Marine Eqpt & Supplies Pumps - Mfrs & Distrs
Dispensers - Liquid Meters Pumps - Service Station Gasoline Dispensing
Generators Nozzles Service Station Eqpt & Supplies
Hose, Couplings & Fittings Pipes Tanks
Lubricating Devices & Equipment Pneumatic Eqpt Components Valves
 
     
   
* * *
* * *
 

40, Gul Crescent, Singapore 629540
Tel : +65 - 6558 7130 ; Fax : +65 - 6558 7132/31
Email : shcengrg@shcsb.com.sg
Website :
www.shce.com.sg ; www.epex.com.sg

 

Corporate Profile

SHC Engineering (formerly known as WOG International Co Pte Ltd) commenced business in 1976, with the aim of providing services to water, oil and gas industries in this region.

SHC Engineering is part of See Hoy Chan Group with business interest in formation technology, asset management, financial services, general insurance, property investments, facilities management and skills training.

As a member of Petroleum Equipment Institute of USA (PEI) since 1983, SHC has been appointed agent, exclusive distributor and stockist by many leading manufacturers from the United States and Europe for this region.

Services Provided

Importing, exporting and supplying of materials and equipment for the water, oil and gas industries.

Design, fabrication, installation, commissioning and maintenance of petroleum storage terminal, automobile service stations and aviation fuel hydrant systems.

Providing solutions to fuel monitoring, fuel management  and fleet management system.

OUR PRODUCT BRANDS INCLUDE :

 
BENNET PUMPS TRICO OILERS
  - Commercial / Retail Dispensers   - Level Guages

DURAPIPES FPP Meters
  - Underground Piping   - Water Flowmeters & Oil Flowmeters

EMCO WHEATON   - Precision Flowmeters

 

- Dry Break Couplers / Adapters   - High Pressure Flowmeter

 

- Aviation Nozzles   - Relays | Accessories

 

- Tank Truck Fittings PERMA TANKS

 

- Loading Arms   - Underground Storage Fibreglass Tank

ELAFLEX LIQUID CONTROLS METERS

FAIRCHILD   - Flowmeters
  - Electro-Pneumatic Transducers EBW
  - Pneumatic Pressure Regulators   - Underground Storage Tank Equipment
  - Volume Boosters   - Aboveground Storage Tank Equipment
  - Power Transmission   - Spill Containers and Manholes / Nozzles
  - Relays / Accessories   - Suction System Equipment

HUSKY FE PETRO

 

- Swivel Joings   - Icon System

 

- Nozzles   - Submersible Pumps
FILLRITE HANNAY REELS
  - Mechanical Flow Meters   - Hose Reels
  - Digital Flow Meters OPW
  - Pumps (Transfer Pumps, Hand Pumps, Rotary Pumps)    
 
 

PERMATANK

FRP / STEEL
Double Wall
Underground Storage Tank

Service Station and Above Ground Tank Fitting

   
 

Mechanical and Electronic Dispensing Pump

   
 

     

Industrial Flow Meter
and Dispenser

   

Manual and Spring
Rewind Hose Reel
for Oil, Aviation Fuel
and LPG

 

   

Aviation Hose
and
Expansion Joint

Precision Pneumatic and
Electro
Pneumatic Controller


 

   


Sight Glass & Oiler

      

 

For more information:-
Tel : +65 - 6558 7130
Email :
shcengrg@shcsb.com.sg


Energy Conservation Technology

Ecogen Energy System is based on a technology acquired from Australia, the results of many years of extensive research and development carried out at the University of Melbourne, Australia.

As energy costs are becoming expensive, the demand for efficient hot water generation system is getting increasingly popular. Today, the Ecogen Energy System is manufactured and marketed under a joint-venture agreement in Malaysia by Linear to cater for the markets in Asia and Middle East.

 

Co-generating Hot Water & Free Cooling

 

Ecogen Energy System works on the same principle as an air-conditioner in the reversed cycle.

The compressor compresses the refrigerant vapour and directs the hot compressed vapor refrigerant to the copper tube coiled round the water storage tank. This makes the coil to act as the condenser and gives out heat energy that is transferred to the water in the storage tank by way of conduction.

The cooled liquid refrigerant is then passed through the liquid receiver to filter the liquid content from the refrigerant vapour. The filtered refrigerant is expanded through the expansion valve and is passed through the evaporator inside or outside the unit where heat from the surrounding is absorbed into the vapour. The refrigerant then flow back to the compressor to complete one cycle of process.

This heating process will keep running until water temperature reaches 57 ±3°. P&T valve is used to ensure the pressure and temperature of the storage water does not exceed the set limits.

 

1

  Heat Pump
    This upper section of the Ecogen Energy System consists essentially of the compressor, evaporator, liquid receiver and expansion valve.
     

2

  Cold Air Discharge
    Chilled fresh air at about 10 °C less than the ambient is ductable from here to the desired location for 'spot cooling' of ventilate an enclosed area.
     

3

  Evaporator
     

4

  Expansion Valve
     

5

  Compressor
     

6

  Pressure Injected Insulaton
    CFC-free polyurethane foam provides heat insulation to the hot water.

 

In residences, food chains, launderettes, hair salons, etc, the Ecogen Energy System in single module up to three modules can be used to supply hot water for consumption of 6 persons to 15 persons for shower, washing and cleaning.

In commercial applications, where there is a consistently high demand of hot water such as hotels, hospitals, dormitories, sports clubs, the Ecogen Energy System in multiple modules can be used to replace conventional gas-fired/oil-fired boilers or electric heaters from 30 rooms onwards.

While hot water is generated with much improved efficiency resulting from the COP of the heat pump refrigerant cycle, the 'free cooling' produced by the evaporator in the heat pump unit can be used to ventilate areas like laundry room, patios, garage, workshop, kitchen, motor room, etc.

Ecogen Energy System is synonymous with cogeneration, simultaneously producing hot water and cool air.


Benefit of Ecogen Energy System

1. Modular Design

Ecogen Energy System comes in different module sizes.

The Series RC with a 1.1kW compressor is completely self-contained and is suitable for the residential, food chain, launderette, hair salon, etc.

The Series CC has a 1.8kW compressor with the evaporator separately mounted designed for multiple-module configuration especially for the commercial segment like hotels, hospitals, dormitories and sports & country clubs.

Both Series RC and CC have a 340 liter storage capacity for one single module.

 

2. Very Low Operating Cost

It uses only approximately 30% the power needed by electric heater to heat the same amount of water. It merely 'pumps' the heat from one location to another.

 

3. Eliminates Conventional Fuel Boiler Cost

It completely eliminates all costs associated with boiler system such as chimneys, ducting, fans, fire-safety system and fuel piping system.

 

4. Eliminates Hazards

It completely eliminates the needs to handle any hazardous fuels.

5. Low Maintainance Cost
Compared to conventional fuel boiler, the maintenance cost is minimal. Ecogen Energy System only requires yearly anode checks and cleaning of air vent.

 

6. Free Cooling

Ductable chilled fresh air at about 10 °C less than the ambient can be channelled to the desired location for 'spot cooling' or ventilate an enclosed area. Hence, downsizing the air-conditioning equipment is also possible.

7. Attractive Payback Period

Compared to the electric heater, the extra investment spent on the Ecogen Energy System can be recovered in a short period of 20 months. Thanks to the COP of the heat pump refrigerant cycle.

8. No Contamination

Most heat pump water heaters have their hot and aggressive vapor refrigerant tube immersed in the storage water. This poses the danger of the storage water to be contaminated by the refrigerant whether be they R134a or R22 which all contain the hazardous chemical Asphyxiate.

BOC Refrigerant Technical Guide states the following precautions in use.

Wear safety goggles, leather/plastic protective gloves, overalls and safety shoes when    handling cylinders.
Use only in well ventilated areas. Ventilate to prevent accumulation of high    concentrations of R134a and ensures the oxygen level in the air is greater than 18%.

 

Ecogen Energy System does not pose any threat of contamination to the storage water in the event that the refrigerant coil is NOT immersed in the water.

 

Air Link Water Heater

 Working Principles

The Ecogen Air Link Water Heater can be installed anywhere where hot water needed. The Air Link water tank is linked to the split air-conditioner system which comprises a condenser, expansion valve, evaporator and compressor. Thus the whole system can be explained by using two loop.

Firstly, the refrigerant loop which incorporates the split air-conditioner system. Heat is absorbed from the surrounding environment by the evaporator to heat the refrigerant. Then, the refrigerant evaporates into the compressor where it is compressed and superheated. Then, the superheated compressed refrigerant passage through the copper tube coiled round the Air Link water tank. This makes the coil act as the condenser and gives out heat energy that is transferred to the water in the tank by conduction. The refrigerant gas then passes through the condenser where it is further condensed into liquid. Upon passage through the expansion valve, the refrigerant is super-cooled and returned to the evaporating unit to complete the refrigerant loop.

   

Secondly, there is the water flow loop. This loop stretches from the inlet of cold water from the water source to the outlet of hot water for the bathroom, kitchen and laundry. This loop is related to the refrigerant loop where the process of heat energy transfer from the superheated refrigerant to the water takes place

   
   

Benefits of Ecogen Air Link Water Heater

 

  • Zero Operating Cost
    Ecogen Air Link Water Heater generating hot water with zero cost at all time
  • Great Saving on Electricity
    Ecogen Air Link Water Heater reduces work done by condenser of the split unit air-conditioner. Thus less wattage of electricity is consumed.
  • Environentally Friendly
    By recycling the waste energy of the air-conditioner, the Ecogen Air Link Water Heater actually helps to conserve the environment.
  • Safe and Quite
    The whole system does not have flame, exhaust, fume and overheating. It also has no motor and any moving parts.
  • Weather Resistant
    Built from highly durable material, the product is strong enough to withstand any weather condition.
  • Minimum Maintenance
    Y early general inspection as deemed necessary.

 

Sectional View of Ecogen Air Link Water Heater

 

1.        Pressure Injected Insulation
CFC-Free polyurethane foam provides heat insulation to the hot water

2.        Pressure and Temperature Relief Value

3.        Hot Water Outlet

4.        Cold Water Inlet

5.        Inner Tank
High gauge steel glass-lined inner and outer surface sand-blasted, epoxy primed and finished with 2 layers of high quality point.

6.        Heating Coil

7.        Thermostat
Automatically cuts off once detects the water temperature reaches 57+/ - 3 degrees

   